Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1528851

RESUMO

The present study analyzed the microhardness and degree of conversion of three Bulk Fill resins (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill and M3 - Opus Bulk Fill) polymerized by single peak and polywave Light-emitting Diode Curing Lights. A total 90 test specimens (n=10) were obtained using a Teflon matrix for the purpose of testing microhardness; and for degree of conversion: 135 specimens (n=5) by using a 2 x 6 cm matrix. The specimens were light polymerized using 3 light sources (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). They were kept in artificial saliva om an oven at 37±1°C during the experiment. The degree of conversion was measured by FTIR 24 h after obtaining each test specimen. The microhardness readouts were performed with a microdurometer at the time intervals of 48 hours (T0), 7 days (T1), 14 days (T2) and 21 days (T3). M1L3 was found to show the highest microhardness values in T2, and M1 showed the lowest degree of conversion in the deep third with L1. It was concluded that Filtek Bulk Fill resin showed the best results in comparison with the other resins.


El presente estudio analizó la microdureza y el grado de conversión de tres resinas Bulk Fill (M1 - Filtek Bulk Fill; M2 - Tetric N-Ceram Bulk Fill y M3 - Opus Bulk Fill) polimerizadas por lámparas de curado de diodo emisor de luz de pico único y polionda. Se obtuvieron un total de 90 especímenes de prueba (n=10) utilizando una matriz de teflón con el propósito de probar la microdureza; y para grado de conversión: 135 especímenes (n=5) utilizando una matriz de 2 x 6 cm. Las muestras se fotopolimerizaron utilizando 3 fuen- tes de luz (L1 - Optilight Max, L2 - Bluephase, L3 - VALO). Se mantuvieron en saliva artificial en estufa a 37 ±1°C durante el experimento. El grado de conversión se midió por FTIR 24 h después de obtener cada muestra de prueba. Las lecturas de microdureza se realizaron con un microdurómetro en los intervalos de tiempo de 48 horas (T0), 7 días (T1), 14 días (T2) y 21 días (T3). Se encontró que M1L3 mostraba los valores más altos de microdureza en T2, y M1 mostraba el grado más bajo de conversión en el tercio profundo con L1. Se concluyó que la resina Filtek Bulk Fill mostró los mejores resultados en comparación con las demás resinas.

2.
Braz. j. oral sci ; 22: e230282, Jan.-Dec. 2023. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1510253

RESUMO

Aim: Evaluate the roughness, microhardness and color change of different Bulk Fill resins when submitted to the condition of gastroesophageal reflux and bulimia. Methods: 60 specimens (n = 10) of Bulk-Fill composite resins were made: M1 ­ Filtek™; M2 ­ Tetric N-Ceram and M3 ­ OPUS, through a matrix 2x6 mm and light cured by the VALO light source. After polishing, initial analyzes (48 hours - T0) of surface roughness (Ra), microhardness (VHN) and color change (ΔE) were performed. To simulate the oral condition of severe gastroesophageal reflux and bulimia, the specimens were immersed in hydrochloric acid (S1) (pH 1.7) 4 minutes a day, for 7 days. Control group specimens were immersed in artificial saliva (S2). Subsequently to immersions, mechanical brushing was performed for 3 minutes, three times a day, simulating 7 days of brushing. And again, the analyzes of Ra, VHN and ΔE were performed (7 days - T1). Thus, hydrochloric acid immersion, mechanical brushing and Ra analysis were repeated at 14 days (T2) and 21 days (T3); and T2, T3 and T4 (3 years) for VHN and ΔE. Results: After Shapiro-Wilk statistical test, ANOVA and Tukey test with Bonferroni adjustment (p>0.05), M3 showed the lowest Ra at all times compared to the other resins, while the highest Ra was at T0. M1 and T1 showed higher VHN. And M2 and T4 showed higher ΔE. Conclusion: Bulk Fill resins can be indicated for patients with Gastroesophageal Reflux and Bulimia, nonetheless, Tetric N-Ceram resin showed the worst results


Assuntos
Cor , Resinas Compostas , Dureza , Ácido Clorídrico , Refluxo Gastroesofágico , Bulimia
3.
Braz. dent. sci ; 25(4): 1-8, 2022. tab, ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1400986

RESUMO

Objective: To analyze the wettability on the surface of eroded dentin in teeth submitted to abrasive wear with desensitizing dentifrices. Material and Methods: Bovine dentin specimens were polished and immersed in 10 mL of citric acid (pH=3.2) for 2 h. The eroded specimens were submitted to mechanic brushing according to the 4 dentifrices adopted: Colgate Total (control); Colgate Sensitive Pro-Relief; Sensodyne Repair & Protect; or Sensodyne Rapid Relief. Afterwards, it was conditioned in 37% aqueous phosphoric acid solution. Wettability of 80 specimens (n=10) brushed for 7 or 21 days was evaluated by measuring the contact angle between the dentin surface and a drop of the adhesive Single Bond Universal® (3M) with a goniometer. Changes in the surface morphology of 12 specimens (n = 3) brushed for 21 days were followed by confocal laser scanning microscopy (CLSM). Data were analyzed by two-way ANOVA and Tukey test (p > 0.05). Results: Groups treated with desensitizing dentifrices did not differ significantly (p ≤ 0.05). Surface treatment and abrasive wear did not interact significantly (p ≤ 0.05). Brushing along 7 days gave the smallest contact angle value (p ≥ 0.05). CLSM images showed morphological changes for all the groups. Conclusion: The desensitizing dentifrices did not interfere in eroded dentin wettability after brushing along 7 or 21 days. Brushing with any of the dentifrices along 21 days promoted open dentinal tubules.(AU)


Objetivo: Analisar a aplicação de um adesivo na superfície de dentina erodida em dentes submetidos ao desgaste abrasivo com agentes dessensibilizantes. Material e Métodos: Espécimes de dentina bovina foram polidos e imersos em 10 mL de ácido cítrico (pH=3,2) por 2 h. Os espécimes erodidos foram submetidos à escovação mecânica de acordo com os 4 dentifrícios adotados: Colgate Total (controle); Colgate Sensitive Pro-Alívio; Sensodyne Repair & Protect; ou Sensodyne Rápido Alívio. Em seguida, foram condicionados em ácido fosfórico a 37%. A molhabilidade de 80 espécimes (n=10) escovados por 7 ou 21 dias foi avaliada medindo-se o ângulo de contato entre a superfície dentinária com uma gota do adesivo Single Bond Universal® (3M) por um goniômetro. Alterações na morfologia da superfície de 12 espécimes (n = 3) escovados por 21 dias foram seguidos por Microscopia Confocal de Varredura a Laser (MCVL). Os dados foram analisados por ANOVA dois fatores e teste de Tukey (p > 0,05). Resultados: Os grupos tratados com dentifrícios dessensibilizantes não diferiram significativamente (p ≤ 0,05). O tratamento de superfície e o desgaste abrasivo não interagiram significativamente (p ≤ 0,05). A escovação ao longo de 7 dias apresentou o menor valor de ângulo de contato (p ≥ 0,05). As imagens do MCVL mostraram alterações morfológicas para todos os grupos. Conclusão: Os dentifrícios dessensibilizantes não interferiram na molhabilidade da dentina erodida após escovação ao longo de 7 ou 21 dias. A escovação com qualquer um dos dentifrícios ao longo de 21 dias promoveu a abertura dos túbulos dentinários (AU)


Assuntos
Animais , Bovinos , Escovação Dentária , Molhabilidade , Dentifrícios , Dentina , Dessensibilizantes Dentinários
4.
J Conserv Dent ; 24(4): 379-383, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35282585

RESUMO

Aim: This study evaluates Vickers microhardness and surface roughness in Biodentine cement (M1) and glass-ionomer cement Fuji IX (M2), both immersed in mouthwash. Materials and Methods: Fifty-four samples were randomly distributed in distilled water (S1), Listerine Cool Mint (S2), and Colgate Plax (S3). Each sample was put in a flask with mouthwash for 2 min, under vibration, twice a day for 21 days. Microhardness and surface roughness were assessed at 48 h (T0), 7 days (T1), 14 days (T2), and 21 days (T3). Results: For roughness: time (T), solution (S) and material (M), TxM, and SxM and for microhardness: M, TxS, TxM, and SxM were statistically significant. T3, M1, M1T3, and M1S1 presented the highest surface roughness. M2, M1T0, M1T1, M1T2, M1S1, and M1S2 presented higher microhardness. Conclusion: Biodentine showed higher surface roughness for T1, T2, and T3 and higher microhardness for T0, T1, and T2 against Fuji IX. Biodentine presented higher microhardness independently of solution.

5.
Rev. odontol. UNESP (Online) ; 47(5): 333-339, Sept.-Oct. 2018. tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-985722

RESUMO

Introduction: The color stability of resin cements, whether dual-pre-cured or photopolymerizable, as well as the color of the dental substrate, are fundamental for the aesthetic success of ceramic restorations, since the ceramic presents a high level of translucency due to its small thickness. Objective: The aim of this in vitro study was to evaluate the color of a resin cement light polymerized by different light sources and immersed in potentially staining beverages. Material and method: Were made 42 specimens of resin cement Variolink-Esthetic (2×6mm) (n=7), being half polymerized with LED light (F1) and half with Halogen light (F2). The specimens were stored in artificial saliva at 37 °C±1 °C. After 24 hours, they were polished with abrasive discs, and divided for the purpose of being submitted to the different solutions for 2 minutes per day, for 28 days, as follows: S1 - Coca-Cola; S2 - Red Wine; and S3 - Distilled Water (Control). Five color readouts were taken: T0 - initial; T1 - 7 days; T2 - 14 days; T3 - 21 days; and T4 - 28 days; with a spectrophotometer (Model SP62S). The color change data (ΔE*) were submitted to statistical analysis, ANOVA and Tukey (p≤0.05). Result: Analyzing the factor solution, S2 (5.89 (±0.02)), produced a higher ΔE* value than S1 (3.79 (±0.02)) and (S1), a higher value than S3 (1.41 (±0.02)). Analyzing the factor light source, F2 (4.05 (±0.12)), produced a higher ΔE* value than F1 (3.33 (±0.12)). When analyzing the factor time, ΔE* values were found to increase gradually over the course of time: T1(2.36 (±0.08)); T2(3.27 (±0.08)); T3(4.06 (±0.08)); and T4(5.09 (±0.08)). Conclusion: It was concluded that red wine produced a greater color change; Halogen light promoted highest degree of pigmentation; and the longer the time of immersion, the greater the color change of the material.


Introdução: A estabilidade de cor dos cimentos resinosos, sejam eles de presa dual ou fotopolimerizáveis, assim como a cor do substrato dental, são fundamentais para o sucesso estético das restaurações cerâmicas uma vez que a cerâmica apresenta alto nível de translucidez devido a sua pequena espessura. Objetivo: O objetivo deste estudo in vitro foi avaliar a cor de um cimento resinoso fotopolimerizado por diferentes fontes de luz e imersos em bebidas potencialmente corantes. Material e método: Foram confeccionados 42 espécimes do cimento resinoso Variolink-Esthetic (2×6mm) (n=7), sendo metade fotopolimerizado com luz LED (F1) e metade com luz Halógena (F2). Os espécimes foram mantidos em saliva artificial à 37 °C±1 °C. Após 24 horas, foram polidos com discos abrasivos e subdivididos para serem imersos 2 minutos por dia, durante 28 dias, nas diferentes soluções: S1 - Coca-Cola; S2 - Vinho Tinto; e S3 - Água destilada (controle). Foram realizadas 5 leituras de cor: T0 - inicial; T1 - 7 dias; T2 - 14 dias; T3 - 21 dias; e T4 - 28 dias; com auxílio de um espectrofotômetro (modelo SP62S). Os dados de alteração de cor (ΔE*) foram submetidos a análise estatística, ANOVA e Tukey (p≤0,05). Resultado: Analisando o fator solução, S2 (5,89 (±0,02)), proporcionou maior ΔE* que S1 (3,79 (±0,02)) e este (S1), maior que S3 (1,41 (±0,02)). Analisando o fator fonte de luz, F2 (4,05 (±0,12)), proporcionou maior ΔE* que F1 (3,33 (±0,12)). E analisando o fator tempo, obteve-se que ΔE* foi gradativamente aumentando no decorrer do tempo: T1(2,36 (±0,08)); T2(3,27 (±0,08)); T3(4,06 (±0,08)); e T4(5,09 (±0,08)). Conclusão: Conclui-se que o vinho tinto promoveu maior alteração de cor; a luz Halógena promoveu maior pigmentação e; quanto maior o tempo de imersão, maior alteração de cor do material.


Assuntos
Saliva , Técnicas In Vitro , Cor , Cimentos de Resina , Cura Luminosa de Adesivos Dentários , Reparação de Restauração Dentária , Luz , Vinho , Pigmentação , Espectrofotômetros , Análise de Variância , Corantes
6.
Pediatria (Säo Paulo) ; 33(2): 107-116, 2011. tab
Artigo em Português | LILACS | ID: lil-610177

RESUMO

Objetivo: Apresentar uma revisão da literatura e descrever os diferentes métodos de sedação consciente utilizados para o tratamento odontológico em pacientes com necessidades especiais e odontopediátricos, dando ênfase na terapia com benzodiazepínicos e na inalação da mistura dos gases óxido nitroso e oxigênio. Fontes Pesquisadas: Livre escolha de artigos científicos e livros relacionados à sedação consciente. Síntese dos Dados: Existem diversas técnicas usadas como recursos alternativos à anestesia geral para o controle e manejo da ansiedade, da dor, do medo e do comportamento em pacientes odontopediátricos e pacientes especiais. Estes métodos incluem modalidades do tipo psicológicas (não-farmacológicas) e farmacológicas. Contudo, em alguns pacientes os métodos não farmacológicos ainda não são suficientes para conseguir a compreensão e a cooperação desejada para possibilitar a realização do tratamento odontológico. Desta maneira, o cirurgião-dentista pode utilizar diversos recursos farmacológicos, como agentes sedativos, analgésicos e outros fármacos úteis para sedação destes pacientes. Dentre os métodos farmacológicos conhecidos de sedação consciente, os mais empregados em Odontologia são os que utilizam os benzodiazepínicos por via oral e a técnica inalatória por meio da mistura de óxido nitroso e oxigênio. Conclusões: A sedação consciente deve ser utilizada para procedimentos odontológicos específicos e situações em que o paciente se beneficie da sedação consciente como método farmacológico de abordagem no controle da ansiedade, da dor e do medo.


Objective: To perform a literature review and describe the several methods of conscious sedation used for the dental treatment in patients with special needs and children with emphasis in benzodiazepines therapy and the mixture of nitrous oxide and oxygen gases. Data Source: Free choice of pertinent literature scientific articles and books related to conscious sedation. Data Synthesis: There are several techniques as alternative resources to the general anesthesia for the control and handling of the anxiety, pain, fear and the behavior in children and patients with special needs. These methods include psychological (non-pharmacological) and pharmacological approaches. However, in several subjects, the psychological methods are not still enough to achieve the desirable cooperation and understanding to perform dental treatment. In this way, the dentist has available several pharmacological resources such as sedative, analgesic agents and other useful drugs for the handling and control of these patients. Among the most known pharmacological methods of conscious sedation, the most used in Dentistry are the oral benzodiazepines and the mixture of nitrous oxide and oxygen gases. Conclusions: Conscious sedation should be used for dental procedures and specific situations in which patients will benefit from conscious sedation as a method of approach in the pharmacological control of anxiety, pain and fear.


Assuntos
Humanos , Masculino , Feminino , Criança , Analgesia , Criança , Odontopediatria , Sedação Consciente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...